Reliable Temperature Monitoring for Dry Ice & Cold Chain Applications
The Polwax PTRANS TD90 is an ultra-compact, single-use USB temperature data logger designed for accurate monitoring of temperature-sensitive products during transportation and storage. With an operating range of -90°C to +70°C, the TD90 is ideal for dry ice shipments, pharmaceuticals, vaccines, biotechnology samples, medical products, and other critical cold-chain applications.


Single Use Dry Ice Data Logger
PTRANS TD90
- Single-Use Functionality
- High Accuracy ±0.4°C for critical Temperature monitoring
- User-Friendly Interface
- USB 2.0 Interface
- Rugged Design
- Plug-and-Play Report Generation
- Wide Application Range
- Up to 4 individually programmable alarm
- Standards Compliant – Meets
- Web, desktop & mobile software support
The Polwax PTRANS TD90 is a compact and cost-effective single-use temperature data logger engineered for monitoring temperature-sensitive products throughout the cold chain.
Designed specifically for demanding low-temperature applications, it provides reliable temperature recording from -90°C to +70°C. The device is suitable for transportation and storage of pharmaceuticals, vaccines, biotechnology materials, medical devices, perishable products, and other temperature-sensitive goods.
Product Overview
The Polwax PTRANS TD90 is an ultra-compact, single-use temperature data logger specifically designed for monitoring temperature-sensitive products during transportation and storage. With a wide measurement range of -90°C to +70°C, the PTRANS TD90 is particularly suitable for dry ice shipments and other applications where reliable monitoring at ultra-low temperatures is essential. It provides accurate, continuous temperature recording to help maintain product integrity throughout the cold chain.
The PTRANS TD90 is developed for critical cold-chain applications where temperature excursions can affect product quality, safety, and usability. It can be used for monitoring pharmaceuticals, vaccines, biotechnology samples, medical devices, perishable goods, and other temperature-sensitive products during transportation and storage. By maintaining a detailed record of temperature conditions throughout the shipment journey, the logger helps users verify that products have remained within their specified environmental conditions.
Designed with simplicity and efficiency in mind, the PTRANS TD90 provides a pre-programmed, user-friendly monitoring solution. The device uses a manual start mechanism, allowing users to begin recording when the shipment is ready. Once activated, the logger records temperature data according to the configured logging interval. The logging interval can be configured from 1 minute to 24 hours, with a default setting of 5 minutes, allowing the device to capture detailed temperature history throughout the monitoring period.
The logger provides substantial storage capacity, with memory for up to 33,000 temperature readings. This allows users to maintain a detailed record of temperature conditions throughout a shipment or monitoring period.
Technical Data
Model No
PTRANS-T90
Product Type
Single-Use Dry Ice Temperature Data Logger
Display
With Display
Input Parameters
Temperature
Operation Temperature
-90℃~70℃
Measurement Accuracy
±0.5°C@-10~40℃,±0.8℃@-30~-10℃&40~70℃ ,±1°C@-90~30℃
Protection Class
IP65
Dimensions
105*40*10mm
Resolution
0.1°C
Weight
30g
Start Mode
Manual start
Report Format
PDF/CSV/PDF&CSV(Optional, congured before leaving the factory)
Logging Interval
1 minute -24 hours optional(Default 5 minutes)
LED Indicator
Green(Recording,OK), Red(Alarm)
Battery life
Up to 60 Days(1 year storage /60 Days useful life) 5 minutes logging interva
Start Delay
0 minute -24 hours optional(Default 10 minutes)
Memory Space
Up to 33,000 points
Battery Type
3.6V Lithium Battery
Certification
CE,EN12830:2018,RTCA/DO-160G,RoHS
Connection
USB2.0
Alarm Limit
Up to 2 individually programmable alarm limits(Alarm threshold and
over-temperature trigger
time can be customized according to customer needs)
Language
English
Scope of Supply
Datalogger with Sealed Plastic Pouch, Test Certificate, Instruction Manual
Configuration Software Link
Key Features
Ultra-Low Temperature Monitoring
Monitor temperature accurately across an exceptionally wide range of -90°C to +70°C. With 0.1°C resolution and specified accuracy across the operating range, PTRANS TD90 is designed for dry ice shipments, pharmaceuticals, biotechnology samples, medical products, and other temperature-sensitive applications.
Easy USB Reporting & Data Retrieval
Retrieve recorded temperature data quickly through the built-in USB 2.0 interface. After monitoring is complete, simply connect the logger to a computer to generate the configured PDF, CSV, or PDF & CSV report, without requiring additional software, drivers, or an internet connection.
Reliable Single-Use Cold Chain Monitoring
Designed for shipment-level monitoring with IP65 protection, up to 33,000 readings, programmable alarms, and clear LED status indicators for reliable cold-chain temperature tracking.
Applications
Why Choose Polwax Single Use Dataloggers?
Key Benefits
- Prevent product damage during transport
- Ensure regulatory compliance (Pharma & Food)
- Reduce operational complexity
- Cost-effective monitoring solution
- Easy deployment with plug-and-play setup
Key Advantages
- Pharmaceutical & vaccine transport
- Food & dairy logistics
- Blood bank & healthcare
- Biotech sample storage
- Cold chain warehousing
- Export shipments (fruits & perishables)
Why Choose Polwax
- Industry-proven cold chain monitoring solutions
- Trusted by pharma, food & logistics companies
- High accuracy & reliability
- Easy-to-use and compliance-ready devices
- Strong technical support
FAQs:
A single use datalogger is a disposable device used to monitor temperature and humidity during transportation and storage of sensitive products without the need for return or reuse.
They are widely used in pharmaceutical, food, biotech, healthcare, and cold chain logistics industries to ensure safe storage and transport conditions.
The device is activated before shipment, records temperature data at set intervals during transit, and generates a report that can be accessed via USB after delivery.
Polwax Single Use Dataloggers typically operate within a temperature range of -30°C to 70°C, suitable for most cold chain applications.
Documents
Software
Protect Every Shipment with Single-Use Data Loggers
The Polwax PTRANS-T10, PTRANS-TD10, PTRANS-T20 & PTRANS-RH20 Single Use Data Loggers provide accurate temperature and humidity monitoring for pharmaceuticals, vaccines, biologics, food products, cold chain logistics, and healthcare shipments. Designed for one-time use, these compact USB data loggers ensure secure data recording, easy PDF report generation, and compliance with global transportation standards. Contact our experts for product specifications, pricing, and the ideal shipment monitoring solution.
Request a Free Quote